Operating temperature
:
PE, PVC: atmosphärisch PPH : 90 °C, PVDF: 100 °C
Operating pressure
:
atmosphärisch
Resistance value of line monitoring
:
22 kΩ / 100 kΩ je nach Ausführung
Operating temperature
PE
:
atmosphärisch
PVC
:
atmosphärisch
PPH
:
90 °C
PVDF
:
100 °C
Technical specifications electronic part
Operating temperature
:
–20...+85 °C
Storage temperature
:
–30...+85 °C
nominal voltage
:
24...30 V DC
Power consumption
:
max. 2 W
Switching voltage
:
max. 230 V AC / V DC min. 5 V DC (CMOS-Relais)
Switching current
:
max. 0,12 A AC / A DC min. <1 mA
Switching capacity
:
max. 25 VA / W
Sensitivity
:
3k … 100 kΩ
T209-0.F
Magnetic immersion probe overfill protection for Ex zone 0 (Cat. 1)
The magnetic immersion probes T20... are used to detect fill level limit values in containers for liquid media, where an explosive atmosphere of zone 0 (cat. 1) is present in the gas space above the liquid and Ex zone 1 (cat. 2) is present outside the container, in the area of the junction box.
Properties
connection
:
Polyesterdose, Aluminiumdose
Protection class
:
IP 65 Dose
Float type
:
Kugel Edelstahl 105 mm Ø
Sliding tube length
:
max. 6000 mm
Operating temperature
:
max. 135°C
Operating pressure
:
max. 20 bar
media density
:
0,54 g/cm³
F-Contact
:
1 / 12 kΩ
Number of additional contacts
:
6x Wechsler, 9x Schließer, 6x Öffner