Ex-QFS-30
:
waagerecht mit G1” Verschraubung, senkrecht mit Beschwerungsgewicht (Ex)
Ex-QFS-31
:
waagerecht mit Flansch ab DN 100 (PP)
TRM-100
Turbidimeter (0...1.000 FNU or 500...4.000 FAU)
The turbidimeter TRM-100 is a compact device for measuring turbidity in liquids. The "turbidity" is measured using the scattered light method (angle 90 degrees) for the turbidity range of < 1,000 FNU (Formazine Nephelometric Units) and the transmitted light method (angle 0 degrees) for the turbidity ranges > 1,000 FAU (Formazine Attenuation Units).
Properties
Operating pressure
:
max. 10 bar @ 20 °C | max. 2,5 bar @ 60 °C
Measuring range
:
500...4.000 FNU / FAU
Measuring accuracy
:
+/-5 %
Mounting position
:
horizontal
Process connection
:
DN 20 | DN 40
Flange connection
:
>= DN 20
number of senders
:
2
number of receivers
:
1
Material
Seal
:
EPDM | optional FPM (Viton)
Process connection
:
PVC | PPH
Measuring tube
:
Borsilikatglas mit Nano Beschichtung
Input
Power supply
:
18...30 V DC
Power consumption
:
< 2 W
Output
Output contact
:
4...20 mA
Switching delay (adjustable)
:
1...10 s
Protection class
:
IP 65
Switching voltage
:
max. 250 V AC | max. 115 V DC
Switching current
:
max. 3 A
Switching capacity
:
max. 500 VA, 60 Watt
Potential-free changeover contact
:
1 @ 1...10 s
ZDS-H
Precision pressure switch for high-pressure applications up to 2,000 bar
Can be used in oil, brake fluid, diesel, air and other gases.
With very good stability and overpressure resistance.
Properties
Pressure range
:
0...2.000 bar gestuft
supply
:
24 V DC
Output
:
Relais 60 V AC/1A
overload
:
1,5 x Messbereich
Med. connection
:
G 1/4 Zoll
electrical connection
:
Schraubklemme
feature
:
Tasten, LCD-Anz.
TK-312
Evaluation unit with 0/4... 20 mA current output
The TK-312 measuring transducer converts the resistance signal supplied from a continuous level sensor into a current signal proportionate to the level.
Properties
Protection class EN60529 clamp
:
IP 20
Protection class EN60529 front panel housing
:
IP 40
Operating temperature
:
–20...+60 °C
nominal voltage
:
24... 230 V AC/DC
Power consumption
:
2 VA, 2W
Dimensions housing type B
:
22,5 x 114,5 x 99
Dimensions housing type C
:
22,5 x 114,5 x 114
Input
Voltage
:
0...10 V
Resistance in three-wire circuit RG
:
0-4...10 kW
Output
Temperature influence tolerance
:
max. ± 0,6 % der Signalspanne
Current output
:
0/4... 20 mA bezogen auf die Masse des Eingangs
Voltage output
:
0/2... 10 V
Mounting
:
Tragschiene nach EN 50022
Weight
:
175 g
XR-6x0 | XR-6x1
Contact protection relay Measuring transducer
The contact protection relays are universal measuring transducers, which
input signals (resistance values) with "Namur" specification (DIN EN 60947).
Namur" specification (DIN EN 60947) into switching signals of floating
output contacts.
Protection class EN60529
clamp
:
IP20
Housing
:
IP40
Technical Data
Operating temperature
:
-20...+60 °C
Storage temperature
:
-30...+80 °C
Output contacts
:
potentialfrei
Switching voltage
:
min. 5 V, max. 250 V AC / 150 V DC
Switching current
:
min. 5 mA, max. 5 A AC / 5 A DC
Switching capacity
:
min. 300 mW, max.100 VA / max. 50 W