Electrode Relays with general approval for constructions Z-65.13-405, Z-65.40-191
Electrode relays for conductive level detection with approved design as part of an overfill cut-out device (Z-65.13-405) / leakage protection (Z-65.40-191)
Properties
details
:
folgen
EF2 24...230 V
Conductive electrodes with 24...230 V direct connection
The EF2 overfill protection (24...230 V AC/DC) is approved by "DIBt" as an overfill protection for liquids hazardous to water.
Operating temperature
:
PE, PVC: atmosphärisch PPH : 90 °C, PVDF: 100 °C
Operating pressure
:
atmosphärisch
Resistance value of line monitoring
:
22 kΩ / 100 kΩ je nach Ausführung
Operating temperature
PE
:
atmosphärisch
PVC
:
atmosphärisch
PPH
:
90 °C
PVDF
:
100 °C
Technical specifications electronic part
Operating temperature
:
–20...+85 °C
Storage temperature
:
–30...+85 °C
nominal voltage
:
24...30 V DC
Power consumption
:
max. 2 W
Switching voltage
:
max. 230 V AC / V DC min. 5 V DC (CMOS-Relais)
Switching current
:
max. 0,12 A AC / A DC min. <1 mA
Switching capacity
:
max. 25 VA / W
Sensitivity
:
3k … 100 kΩ
ELH
Suspension electrode as leakage probe
The leakage probes of the type series ELH are approved by the "DIBt" for the monitoring of collecting chambers, collecting devices, inspection and filling shafts.
General data
Protection class
:
IP 68
Probe body material
:
PE, PVC, PPH, PVDF
Diameter probe body
:
15 mm, 25 mm, 40 mm
Operating temperature
:
atmosphärisch
Operating pressure
:
atmosphärisch
Resistance value of line monitoring
:
22 kΩ / 100 kΩ