The water level gauge is particulary suitable for all liquid media which are aggressively hot and rapidly moved in a container, but are not too much contamined.
Properties
Tank connection
:
Flansch ab DN 25 oder Verschraubung ab G ½"
Material Float
:
PPH max. 2,5 bar, Glas max. 10 bar
cable length
:
bei monostabilem Kontakt: Standard 2 m
Number of contacts
:
beliebig
Contact distance
:
min. 10 mm
Temperature of the fluid
:
mit Plexiglasrohr max. +70 °C
media density
:
ρ ≥ 0,95 g/cm³ | ρ ≥ 0,85 g/cm³ (auf Wunsch)
Properties W-350
Material tube sight glass
:
transparentes PVC
Temperature of the fluid
:
max. +60 °C
Operating pressure
:
max. 2,5 bar
Material flange
:
PVC
Material connection with angle valve
:
PVC
Material sealing ring
:
Gummi
Properties W-351
Material tube sight glass
:
Hartglas, Plexiglas
Temperature of the fluid
:
max. +120 °C
Material flange
:
Rotguss
Material connection with angle valve
:
Rotguss
Material sealing ring
:
Silikon
Operating pressure with glass tube
:
max. 10 bar
Operating pressure with plexiglass tube
:
max. 2 bar
Properties W-352
Material tube sight glass
:
Hartglas, Plexiglas
Temperature of the fluid
:
max. +120 °C
Material flange
:
Edelstahl
Material connection with angle valve
:
Edelstahl 1.4571 als Bogen 90°
Material sealing ring
:
PTFE und Viton
Operating pressure with glass tube
:
max. 10 bar
Operating pressure with plexiglass tube
:
max. 2 bar
Properties W-353
Material tube sight glass
:
Hartglas, Plexiglas
Temperature of the fluid
:
max. +120 °C
Material flange
:
Edelstahl
Material connection with angle valve
:
Edelstahl 1.4401
Material sealing ring
:
PTFE und Viton
Operating pressure with glass tube
:
max. 10 bar
Operating pressure with plexiglass tube
:
max. 2 bar
ZCS-5000
Self-contained CO2 sensor ZCS-5000 in small housing with warning horn
stand alone CO2 sensor for measuring and monitoring carbon dioxide concentration in ambient air.
Properties
Housing
:
Kunststoff
Power supply 24V
:
24V DC | 230V
Measuring element and parameter
Measuring principle
:
optisch, NDIR
measuring grid
:
2 sec.
Accuracy
:
± (50ppm+3% vom Messwert) im Bereich von 300…5.000ppm CO2
Electrode relays for conductive level detection for all areas in which conductive, liquid media are to be detected, controlled or monitored
Properties
Protection class EN60529 clamp
:
IP 20
Protection class EN60529 front panel housing
:
IP 40
Operating temperature
:
–20...+60 °C
Storage temperature
:
–30...+80 °C
AC nominal frequency
:
48...62 Hz
Power consumption
:
max. 1 W / VA
Weight
:
ca. 150 g
Input
Open circuit voltage
:
≤ 10 V AC
Short-circuit current
:
≤ 5 mA
Output
Contacts
:
1 potentialfreie Wechselkontakte pro Kanal
Switching voltage
:
min. 5 V | max. 250 V AC | max. 150 V DC
Switching current
:
min. 5 mA | max. cosφ=1 3A | max. cosφ=0,7 1 A/AC | max. cosφ=1
Switching capacity
:
min. 300 mW | max. 750 VA / 150 W (30 V DC / 5 A) / 18 W (150 V DC / 0,12 A)
Working / Idle current
:
umschaltbar
overvoltage category
:
EN 61010-1 Kategorie III
TK-312
Evaluation unit with 0/4... 20 mA current output
The TK-312 measuring transducer converts the resistance signal supplied from a continuous level sensor into a current signal proportionate to the level.
Properties
Protection class EN60529 clamp
:
IP 20
Protection class EN60529 front panel housing
:
IP 40
Operating temperature
:
–20...+60 °C
nominal voltage
:
24... 230 V AC/DC
Power consumption
:
2 VA, 2W
Dimensions housing type B
:
22,5 x 114,5 x 99
Dimensions housing type C
:
22,5 x 114,5 x 114
Input
Voltage
:
0...10 V
Resistance in three-wire circuit RG
:
0-4...10 kW
Output
Temperature influence tolerance
:
max. ± 0,6 % der Signalspanne
Current output
:
0/4... 20 mA bezogen auf die Masse des Eingangs
Voltage output
:
0/2... 10 V
Mounting
:
Tragschiene nach EN 50022
Weight
:
175 g
HD-1XX
Hydrostatic filling level measurement
Continuous and precise level measurement in unpressurised, open basins and tanks as well as underground applications such as shafts, wells and boreholes.
EF2…5 24V
Conductive electrodes with and without 24 V DC direct connection
The conductive electrodes EF2...5 are approved by the "DIBt" as overfill prevention devices for liquids hazardous to water.
Properties
Protection class EN60529
:
IP 65
connection thread
:
G1" | G1¼" | G1½"
Union nut
:
G2¾" | S 100x8
Operating temperature PE / PVC
:
atmospheric
Operating temperature PPH
:
90°C
Operating temperature PTFE
:
100°C
Operating pressure
:
atmospheric
Resistance value of line monitoring
: