Description
The hydrostatic installed screwed sensors are used for filling level measurements in water and in clean to slightly contaminate liquids as well as in acids, alkaline solutions or aggressive media.
Technical Data
Properties
- Protection class EN60529
- IP 65
- Operating temperature
- -10...70 °C (PVC: -10...60 °C)
- Storage temperature
- -25...70 °C (PVC: -10...60 °C)
- Power supply
- 15...30 V DC
- power
- max. 25 mA
- Output
- 2-Leiter-Technik | 4...20 mA
- Measuring range
- 0,8...10 mWs (Standard) andere Messbereiche auf Wunsch. Der Messbereich ist auf Dichte 1,0 g/cm3 ausgerichtet
- Overpressure
- ca. 20 %
- Deviation from characteristic curve
- Nichtlinearität, Hysterese, Reproduzierbarkeit nach IEC 60770 Standard: ≤± 2%
- Insulation resistance
- > 100 kΩ
- Short-circuit resistance
- permanent
- Reverse polarity protection
- keine Schädigung o. Funktion bei vertauschten Anschlüssen
Materials
- Housing
- Edelstahl 1.4571, PVC, PVDF
- Measuring cell
- Edelstahl 1.4404, Keramik AI2o3 96%, Keramik AI2o3 99,9%
- Seals
- FKM (Viton ®), EPDM, FFKM (Kalrez ®)
- connection thread
- G ¾“ und G 1 ½“
- Plug
- Steckverbindung DIN 43650
HD-11X configuration
Your Configuration
- Basename
- HD11
- Gehäuse
- Anschlussgewinde
- Messbereich
- Ausgangssignal
- Steckverbindung
- Abdichtung
- Sondermesszelle
Further product information
The housings are made of stainless steel 1.4571, PVC or PVDF. The sensor membranes are made of stainless steel 1.4404, ceramics Al2o3 96 %, Al2o3 99,9 %.
By default, the seals are mode of FKM (Viton®). Other sealing mat-erials are EPDM or FFKM (Kalrez®).
The thread is G ¾“ and G 1 ½“. The electrical connection is of plug-in design.
Pressure less containers and tanks represent the application areas.
- Supply voltage 15-30 V DC
- Connection thread G ¾“ and G 1 ½“
- Long-term stability
- Customer-specific design