EF2X

Double pipe and filling pipe monitoring

Caractéristiques

WHG

famille de produits

mesure de niveau

classe de produits

protection anti-débordement et détecteur de fuite

convient pour

Liquide

principe de mesure

conductive


Caractéristiques particulières

  • with general technical approval for construction Z-65.13-405

  • Electronics integrated in the probe

  • High chemical resistance

Description

EF2L and EF2T -conductive- with general technical approval for construction Z-65.13-405

Données techniques

Propriétés
ltdata.Elektr.Anschluss
Stecker GDM
Classe de protection EN60529
IP 65 mit Dichtung
raccordement
PVC Überwurfmutter G 1 ¼“
ltdata.BetriebstemperaturPVC
max. +60 °C
ltdata.BetriebstemperaturPE
max. +80 °C
Température de stockage
-30...+85 °C
Pression de fonctionnement
max. 6 bar
Matériau
Tuyau
PVC | PE
Tiges du capteur
Edelstahl 1.4571 | Hastelloy B/C | Titan | Tantal
tdata.ElektronikteilET-473L|ET-473T
tension nominale
20...30 V DC
Consommation électrique
1 VA
Contact de sortie
Schließer | Öffnerkontakt (NO/NC) (nicht potentialfrei)
Tension de commutation
12...30 V DC
Courant de commutation
max. 300 mA
Capacité de commutation
max. 9 W
Plage de sensibilité
2...30 kOhm
ltdata.

EF2X configuration

EF2 - [ 1 ] - [ 2 ] - [ 3 ] - [ 4 ] - [ 5 ]


1 Typ

  • L : Leckageüberwachung Doppelrohr
  • T : Trockenlaufschutz Befüllleitung

2 Anschluss

  • 00 : PVC-Überwurfmutter G 1 ¼”

3 Rohrmaterial und Anschlußkopf

  • PV : PVC
  • PE : Polyethylen

4 Stabmaterial

  • VA : Edelstahl 1.4571
  • HB : Hastelloy B
  • HC : Hastelloy C
  • TI : Titan
  • TA : Tantal

5 Elektronikteil

  • ET473L : Leckageüberwachung Doppelrohr
  • ET473T : Trockenlaufschutz Befüllleitung

Autres informations sur les produits

The conductive probes EF2L and T with integrated electronics ET-473L and ET-473T are used to monitor double pipes and/or filling pipes. 

The probes are approved by the DiBt for water-polluting liquids.

The conductive electrode EF2L, with integrated electronics part ET-473L, sets off an alarm in the event of leaks in double-walled pipelines. The conductive electrode EF2T, with integrated electronics part ET-473T, sets off an alarm if air instead of medium is present in the filling pipe. The use of these devices is preferred for water-polluting  iquids that require DiBt test certification. The housing material consists of either PVC or PE.

The probe’s electrode tips are made of either stainless steel (1.4571), hastelloy B/C, titanium or tantalum 
depending on the medium.

The electronics part is integrated directly into the probe tube. An optional NC or NO contact (closer or opener) is present at the connector port. Various installation and attachment parts can be supplied for the installation / attachment of the devices.

  • Approved by DiBt according to WHG (Water Resources Act)
  • High chemical resistance
  • Electronics integrated in the probe
  • NO or NC output
  • Leakage / pipeline monitoring
  • Filling pipe monitoring to 
  • protect against pressure surges
  • Available as a complete unit with bonding sleeves, welding sleeves and ball valve

The double pipe and filling pipe moni-toring EF2L and T can be connected to our “optical and acoustic alarm” series OAA-300.

Documents et téléchargements

Accessoires

Nos ingénieurs d'application vous conseillent de manière personnelle, complète et professionnelle !